Lubricant oil can be used as a thermal transfer fluid, commonly known as Hot Oil; in different applications in Gas Production Plants, Asphalts heating, Termosolar Power Plants among others. This fluid usually works as 400 °F.

Sicelub Lubritech Group has background performing High Velocity Oil Flushing Services in Hot Oil System, when a fluid change is scheduled.

The innovation from our company is that we can perform on line filtration, at operational temperature with the following benefits:

  • It is no necessary to stop the system, which optimize production.
  • Fluid life is extended due to the contamination removal.

Firs job we performed in Argentina is an online Filtration to a Hot Oil System with 90,000 liters of fluid in a Gas Production Plant in the south of the country. We used a 100 GPM filtration skid, able to operate at high temperatures (up to 660 °F), and using filter elements with different β factors.

The Service was performed in Tierra del Fuego, parallel 52 South; for 15 days, starting with ISO Code of 26/24/21, reaching ISO Code 15/14/11, improving cleanliness in more than 500 times.

Our technicians involved in the job were Daniel Perez, Marcos Herrera, Andres Frezzini, y Rodrigo Coppiarolo; reporting to Martín Videla.

We would like to thank to our Customer and our team for their commitment. We share some pictures, and if you want to have additional information, please reach us at www.sicelub.com; send an email to info@sicelub.com; or write a WhatsApp message to +34 616 54 70 86.

January is usually a summer holyday month in Argentina and Brazil. In our Company, we have been working in both countries, and we want to share with you our news!

In Brazil, we performed a very important job in a big chemical plant in north of the country. The job was High Velocity Oil Flushing to an Alstom Turbo Generator. We performed cleaning in lubricating, control and jacking systems. Total of lubricant oil is 3,500 Gallons and for the service we used a 2,200 GPM unit, and Thermojet Oil Purifier.

We prepared and Engineering for bypasses and we were able to complete the scope before lead time. Our services were leaded by Alexandre Adao with other 3 lubrication technicians.

In the case of Argentina, we were performing the service in a Steel Mill Plant, where we performed Chemical Cleaning and High Velocity Flushing Services. We finished the job in the scheduled time. You can see a picture of “before” and “after” the cleaning.

We would like to thank to our Customer and our team for their commitment. We share some pictures, and if you want to have additional information, please reach us at www.sicelub.com; send an email to info@sicelub.com; or write a WhatsApp message to +34 616 54 70 86.

Lubritech Perú has successfully completed a Service of reservoir cleaning and lubricant Filtration in TG-01 in a Thermal Power Plant in Perú. More than 3,000 Gallons were extracted from the reservoir, filtered, and added to the reservoir after cleaning. In the attached pictures, dirty is observed in the reservoir prior to cleaning.

When an ISO Code of 16/14/10 (NAS 5) was reached, the job was completed.

Under this cleanliness level start up of the turbine is safer and operation is reliable, according to recommended by ASTM D-4378.

For this job we had 3 lubrication technicians, a 50 GPM filtration unit with β3 higher than 1,000.

Even during January, the team performed a Filtration to an Elliot turbo compressor in a Refinery to reach an ISO Code of 16/14/12. All the process was according to ASTM 6439-99, and we used a 20 GPM equipment with β3 higher than 1,000.

We would like to thanks to our team in Peru, and we go for more!